Reference Studies

In the development of the TRI Performance Concept and corresponding product attributes, substantial literature research was conducted in relation with the scientific board of the TRI project.

Clin Oral Investig. 2010 Aug;14(4):411-6. Epub 2009 Jun 20.

The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis.
Eraslan O, Inan O.

Int J Oral Maxillofac Implants. 2009 May-Jun;24(3):455-62.

Biomechanical effects of a maxillary implant in the augmented sinus: a three-dimensional finite element analysis.

Huang HL, Fuh LJ, Ko CC, Hsu JT, Chen CC

Clin Oral Implants Res. 2002 Dec;13(6):657-65.

Three-dimensional finite element analysis of implant stability in the atrophic posterior maxilla: a mathematical study of the sinus floor augmentation. Tepper G, Haas R, Zechner W, Krach W, Watzek G.

J Oral Implantol. 2009;35(3):130-5.

Effect of implant design on initial stability of tapered implants. Chong L, Khocht A, Suzuki JB, Gaughan J.

J Am Dent Assoc. 2009 Nov;140(11):1366-72.

Clinical methodologies for achieving primary dental implant stability: the effects of alveolar bone density.

Cavallaro J Jr, Greenstein B, Greenstein G.

Clin Oral Implants Res. 2006 Oct;17 Suppl 2:124-35.

Bone density and primary stability in implant therapy. Molly L.

Clin Oral Implants Res. 2010 Nov 19. doi: 10.1111/j.1600-0501.2010.02036.x. [Epub ahead of print]

Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: Is there a relationship? An in vitro study. Trisi P, De Benedittis S, Perfetti G, Berardi D.

Clin Oral Implants Res. 2009 May;20(5):467-71.

Implant micromotion is related to peak insertion torque and bone density.

Trisi P, Perfetti G, Baldoni E, Berardi D, Colagiovanni M, Scogna G

Comput Biol Med. 2010 Aug;40(8):681-6.

Optimal design of thread height and width on an immediately loaded cylinder implant: a finite element analysis.

Ao J, Li T, Liu Y, Ding Y, Wu G, Hu K, Kong L.

 

SLA Reference studies

Clin Oral Implants Res 1996;7(3):240–252.
Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: radiographic results. Cochran DL, Nummikoski PV, Higginbottom FL, Hermann JS, Makins SR, Buser D.

J Biomed Mater Res 1998;40(1):1–11.
Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible. Cochran DL, Schenk RK, Lussi A, Higginbottom FL, Buser D.

J Biomed Mater Res 1999;45(2):75–83.
Interface shear strength of titanium implants with a sandblasted and acid-etched surface: a biomechanical study in the maxilla of miniature pigs. Buser D, Nydegger T, Hirt HP, Cochran DL, Nolte NP.